Category - AqueousMethodsMinimum Qty.Recommended ContainersRequired PreservationHolding Time
Semi-volatile Organics 625/8270 1L 2 x 1 L Amber Glass Bottle w/ Teflon Liner Cool to 4°C; Remove Chlorine 7 Days
Semi-volatile Organics (drinking water) 525.2 1L 2 x 1 L Amber Glass Bottle w/ Teflon Liner Cool to 4° C; HCl to pH<2 Add sodium sulfite 7 Days
Polynuclear Aromatic Hydrocarb. 610/8100 8270 1L 2 x 1 L Amber Glass Bottle w/ Teflon Liner Cool to 4° C Remove Chlorine 7 Days
Category - SolidMethodsMinimum Qty.Recommended ContainersRequired PreservationHolding Time
Semi-volatile Organics 827030g Glass Jar w/teflon liner Cool to 4° C 14 Days
Polynuclear Aromatic Hydrocarb. 8100, 8270 30g Glass Jar w/teflon liner Cool to 4° C 14 Days

Normal Hours of Operation

The lab is open 8:00 AM to 4:30 PM, Monday through Friday

Samples are only accepted according to the following schedule:

Monday through Thursday,  8:00 AM to 4:00 PM; Friday, 8:00 AM to 12:00 PM *Hours will vary to accommodate government holidays.

If you are submitting pool samples: 

  • Pool samples are only accepted between the hours of 8:00 AM and 3:00 PM.
  • Pseudomonas expedited turnaround time (rush order) is limited to 4-day and 5-day only.